Engagements and experienceEnergy storage

The same security in hundreds of BESS units, whoever's network they end up on

A manufacturer was to series-produce battery energy storage (BESS) for customers across Europe. Security was engineered in, so the boundary travels with every unit without on-site configuration.

The situation

A Nordic manufacturer was taking a new battery energy storage system (BESS) from concept to series production, with customers across Europe. Every unit would be connected to local and global grid control and to electric vehicle charging infrastructure, and would end up on a network with a different operator, a different firewall policy and a different view of remote access. Security therefore had to be a property of the product, not something configured on site.

The challenge

Manual security configuration works for a handful of units. At hundreds per year it becomes both a bottleneck on the factory floor and a source of deviations that nobody detects until the unit is in operation at a customer site. At the same time the product speaks industrial protocols towards operational systems and grid control, and connects to charging infrastructure. Every integration that makes the product useful is also a way in.

Series scale

The boundary travels with every BESS.

THE BOUNDARY IN THE PRODUCTOPERATIONSADMINISTRATIONFACTORYNo configurationon siteNET AA different operatorBESSNET BA different firewall policyBESSNET CA different view of remote accessBESSCENTRAL SECURITYMONITORINGTraceability fromevery unitLOG FLOWZONE BOUNDARY IN THE PRODUCTROLLOUTFACTORYNo configuration on siteOPERATIONSADMINISTRATIONNET AA different operatorBESSNET BA different firewall policyBESSNET CA different view of remote accessBESSCENTRAL SECURITYMONITORINGLOG FLOWROLLOUTZONE BOUNDARY IN THE PRODUCT
fig. 1Identical BESS units from the factory, with no configuration on site, on three customer networks with a different operator, firewall policy and view of remote access. The boundary between operations and administration lives in the product and looks the same on every network. The log flow runs from every unit to central security monitoring. The figure shows the pattern, not the product's design.

How it was solved

The decisive choice was to put security into the product architecture rather than into the installation. We designed the OT network and security platform with zone-based separation between operations and administration in line with IEC 62443, with traceability built in. When the boundary exists in the product, it does not have to be recreated at every customer, and it looks the same on every network the unit ends up on.

The second choice was that no factory-new unit would be configured by hand. The rollout was automated so that units are configured without manual handling. That is the precondition for series scale: every delivered unit can be described, and the most common source of variation between units disappears.

The threat analysis was carried out within the client’s own framework, so that the results could be used in decisions without first being translated. We took part in threat analysis and risk assessment (TARA) under the client’s security framework, and the security analyses were reviewed by a third party at an accredited body against the cybersecurity requirements of the Radio Equipment Directive (RED). The log flow from the field operating environment to central security monitoring (SIEM) was built and commissioned as part of the same work. The platform is part of a target architecture and an architectural roadmap for energy storage and energy management systems (BESS/EMS), so that product decisions and business strategy point the same way.

The result

The product is in series production, on the order of hundreds of units per year, with customers across Europe. The security analyses have been reviewed by a third party at an accredited body against the RED cybersecurity requirements. The security platform travels with every delivered unit instead of being rebuilt per installation.